Ozone eddy covariance measurements at Penlee Point Atmospheric Observatory, April-May 2018
This dataset contains wind, temperature, pressure, humidity and ozone mixing ratio, given as the 20-minute mean of 10 Hz (ozone and wind) or 0.25 Hz (pressure, humidity and temperature) raw data. Ozone flux values calculated from the raw 10 Hz wind and ozone data are presented as mass fluxes and as molar fluxes. Deposition velocity is calculated from the molar flux.
Data relevant to the data selection are also included, such as ozone variability, instrument sensitivity, wind stationarity and wind speed and direction. The Penlee Point Atmospheric Observatory (PPAO) site is best suited to observing fluxes over water. The north-west sector contains the sloping headland on which the observatory is built, making flux observations in this sector of limited value.
The footprint area (where the measured flux is occurring) varies with wind conditions, but generally 90% of flux contribution occurs within 2-3 km of the observatory. The building itself sits 30-60m from the coast, depending on tide.
Measurements were taken from 2018/04/10 - 2018/05/21 using a Gill WindMaster Pro sonic anemometer, a Gill MetPak Pro, and a high frequency chemiluminescence ozone detector from Eco Physics. A 2B 205 ozone monitor was used as a reference for the high frequency ozone instrument. Data collection was managed by David Loades (University of York), Thomas Bell (Plymouth Marine Laboratory) and Mingxi Yang (Plymouth Marine Laboratory).
Data are missing where fluxes couldn't be calculated, most commonly due to heavy rain disrupting the anemometer or power outages.
These data were collected for the Natural Environment Research Council (NERC) project Iodide in the ocean:distribution and impact on iodine flux and ozone loss.
Simple
- Date (Publication)
- 2020-02-28T15:33:12
- Date (Creation)
- 2020-02-28T15:33:12
- Identifier
- Centre for Environmental Data Analysis (CEDA) / 8351ed155b134155848d03a7cdce9f02
- Identifier
- doi / 10.5285/8351ed155b134155848d03a7cdce9f02
- Maintenance and update frequency
- Not planned
- Update scope
- Dataset
- Keywords
-
- Ozone
- eddy
- Penlee Point
- GEMET - INSPIRE themes, version 1.0
-
- atmospheric conditions
- Access constraints
- Other restrictions
- Other constraints
- Public data: access to these data is available to both registered and non-registered users.
- Use constraints
- Other restrictions
- Spatial representation type
- Grid
- Metadata language
- English
- Topic category
-
- Climatology, meteorology, atmosphere
- Begin date
- 2018-04-10T00:00:00
- End date
- 2018-05-22T00:00:00
- Unique resource identifier
- WGS 84
- Distribution format
-
-
Data are BADC-CSV formatted.
()
-
Data are BADC-CSV formatted.
()
- OnLine resource
-
CEDA Data Catalogue Page
Detail and access information for the resource
- OnLine resource
-
DOWNLOAD
Download Data
- Hierarchy level
- Dataset
Conformance result
- Date (Publication)
- 2010-12-08
- Statement
- 10 Hz data logged at the Penlee Point Atmospheric. High frequency data were despiked and detrended, and double rotation was applied to the wind vectors for flux calculation. The data were then sent to the Centre for Environmental Data Analysis (CEDA) for archiving.
- File identifier
- 8351ed155b134155848d03a7cdce9f02 XML
- Metadata language
- English
- Character set
- UTF8
- Hierarchy level
- Dataset
- Date stamp
- 2024-09-05T23:18:11
- Metadata standard name
- UK GEMINI
- Metadata standard version
- 2.3